OX100

Portable digital dissolved oxygen meter


The OX100 Dissolved oxygen meter is designed to overcome the traditional problems with field calibration and lack of reliability associated with many DO instruments.

The instrument's robust galvanic cell allows rapid in situ calibration in air, with automatic temperature compensation and simultaneous display of temperature.

The probe consumes very little oxygen making it possible to use with a minimal flow of water. The probe can also be stored dry.

The OX100 compensates for salinity or barometric pressure with simple keypad input. A 16 data set non-volatile memory allows results to be stored whilst in the field and recalled when required. 

DOCUMENTS


FEATURES

  • Automatically Compensates Salinity and Barometric Pressure
    after manual input for increased accuracy
  • Independent 100% and Zero Adjustment Calibrations
    Ensures high accuracy across entire measurement range
  • No Meter Warm-up Required with Galvanic Cell
    measurements ate taken, immediately
  • Stores and recalls 16 data sets
    temperature readings are stored with the data sets
  • Displays Electrode Diagnosis
    gives slope, zero offset and millivolt values to help determine when to service or replace electrode
  • Ready Indicator
    prompts whenever reading stabilizes
  • Hold Function
    momentarily freezes reading for easy viewing and recording
  • Auto-Power Off
    saves battery power after non-use
  • Self-Diagnostic
    with message codes for easy troubleshooting
  • Large Custom LCD
    provides optimum viewing with user-friendly icons
  • Power with Batteries or Optional AC Adapter
    for use in the field or at bench-top with built-in stand

SPECIFICATION

Dissolved Oxygen Range 0 to 19.9 mg/l or ppm
Resolution & Accuracy 0.01 mg/l, 0.1 ppm & ±1.5% Full Scale
% Saturation of Oxygen 0.0 to 199.9 %
Resolution & Accuracy 0.1 % & ±1.5% Full Scale
Temperature Range 0.0 to 100.0 °C
Resolution & Accuracy 0.1 °C & ± 0.3 °C
Salinity Correction 0.0 to 50.0 ppt
Barometric Pressure Correction 555 to 808 mm Hg or 74 to 108 kPA
Method Manual input for automatic correction
No. of Calibration Points Up to 2 points; 100% in air and/ or 0% in known solution
Memory 16 sets
Special Functions Averaging/Stability; Self-diagnostic; Electrode characteristics; Hold & Auto-Power Off after 20 minutes
Power Requirements 4 x 1.4V batteries; > 100 hrs or 9VDC power adapter



To locate your nearest distributor click here

Please click here to the previous page.

DISTRIBUTORS

Click here to view world map
CONTACT US
WPA
Unit 22 - Cambridge Science Park
Milton Road
Cambridge
CB4 0FJ

Tel:
+44 (0) 1223 423723
Fax:
+44 (0) 1223 420164

E-mail:
To contact WPA please click here
COPYRIGHT © WPA - MOST RECENT REVISION 21.11.2008



Website designed by mi